KINGSPAN K12 PDF

Insulation Between, and Insulated Plasterboard Fixed to,. Timber Framework on Solid Brick Wall. Damp proof course. Kingspan Kooltherm®. K12 Framing Board. Total R–values for various thicknesses of Kingspan Kooltherm®. K12 Framing Board and different wall types. Product Thickness. Heat flow in. Heat flow out. Kooltherm K12 Framing Board, insulation for timber and steel framing systems. Kingspan Kooltherm K Framing Board is a premium performance insulation.

Author: Mezidal Voramar
Country: Spain
Language: English (Spanish)
Genre: Sex
Published (Last): 18 August 2017
Pages: 378
PDF File Size: 2.99 Mb
ePub File Size: 18.38 Mb
ISBN: 126-2-28020-817-7
Downloads: 85853
Price: Free* [*Free Regsitration Required]
Uploader: Douran

Delivery throughout The Netherlands. Fix Kingspan Kooltherm K12 Framing Board to the external surface of the frame structure ensuring vertical board joints coincide with a vertical member. Pack Kooltherm k12 70 mm thick High-quality kingspn for parapets, interior walls or post-insulation of pitched roofs. Surfaces must be dry and free from dust, oil or grease prior to taping. Advice should be sought from the appropriate steel frame manufacturer for recommendations of a suitable wall tie specification.

The Kooltherm K12 frame plate has a low Lambda value from 0.

Kingspan Kooltherm K12 – Kingspanshop

If you do not click “Accept and close” but continue to use this website: The contribution of the product Total R-values depends on installation and environmental conditions.

Do you need help and advice on your project? As such, the will reflect light as well as heat, including ultraviolet light. You must have JavaScript enabled in your browser to utilize the functionality of this website. As there’s currently a high demand for wool materials nationwide, most wool orders may take an estimated 4 weeks to deliver. Boards should be stored inside a building. This reflective, low emissivity surface can effectively double the thermal resistance of the cavity in which the board is placed.

  A2FM REXROTH PDF

Kooltherm K12 Framing Board. Share Twitter Facebook LinkedIn. If, however, temporary outdoor storage cannot be avoided then the boards should be stacked flat on a level base, clear of the ground, and completely protected from inclement weather through use of a polythene sheet or weatherproof tarpaulin.

The counter—battens should be fixed at centres to coincide with the timber frame wall studs. For any enquiries, call or send an email to info kingspaninsulation. Fixings should be in accordance with the steel frame manufacturer’s recommendations. The Selwyn Aquatic Centre in Rolleston provides an aquatic experience that can be enjoyed all year round.

Check out our Bestselling Products Bestsellers.

Kingspan Kooltherm K12 Phenolic Framing Board

Construct the outer leaf of masonry in the conventional manner, using appropriate wall ties to hold the two wall leaves together. Minimum order quantities apply. Boards should be stored inside a building. A to Z Product Name: Ensure that safe methods of cleaning are used, as recommended by suppliers of the spilt liquid.

To restrain insulation boards from moving within the timber stud cavity, side nail battens to the stud to provide a ‘stop’. Kooltherm insulation has a fibre-free and closed cell insulation core, which has been manufactured with zero Ozone Depletion Potential and low Global Warming Potential. K12 framing board should be fixed to the external surface of the timber frame structure outside of any OSB or plywood sheathing and restrained using temporary fixing in the form of large headed galvanised clout nails prior to being tied into the masonry leaf with an appropriate timber frame wall tie.

Round Thermahood Downlight Cover. Damaged boards or boards that have been in contact with harsh solvents or acids should not be used. Where additional vapour control is required an appropriate surface treatment should be applied over the completed insulated wall area refer to ‘Water Vapour Control’.

  ENGLISH INTONATION J.C.WELLS PDF

The insulation boards are easily cut to individual studwork spacings. An additional restraint to the boards will be provided by a plasterboard lining fixed to the inside face of the timbers.

The Old Stone House Aged not by years, but by its stories.

By insulating the entire building envelope, or lining internally with insulation, the problem of cold bridging can be eliminated completely. Wall Ties — Timber Frame Wall The outer leaf of masonry may be constructed in the conventional manner using appropriate wall ties to restrain the two wall skins together.

Kingspan Insulation products are chemically inert and safe to use. Pay less and sustainably enjoy doing at Kingspanshop! The reflective, low emissivity surface can effectively double the thermal resistance of the cavity in which the board is placed. Our teams are dedicated to helping make your process as easy as possible and ensure you get the right materials for your building. Checking “Remember Me” will let you access your shopping cart on this computer when you are logged out.

When utilising K12 between studwork, the plasterboard lining should be of the vapour check type or a separate polythene vapour control layer used. However, it is recommended that any spills be cleaned off fully before the boards are installed. To find out more about the cookies we use, or to change your cookie preferences i. Durability If correctly applied, K12 framing board has an indefinite life.